| Sign In | Join Free | My futurenowinc.com | 
 | 
Brand Name : Teledyne
Model Number : R17A
Certification : ROHS
Place of Origin : Teledyne
MOQ : 1PC
Price : negotiable
Payment Terms : T/T
Supply Ability : 1~1000pcs
Delivery Time : on request
Packaging Details : carton
Origin : USA
PRODUCTS : Teledyne Oxygen sensor
Warranty : 3 months
Manufacturer : Teledyne
Packing : Stand packing
shipping terms : EXW
Model : R17A
response time : 45 seconds
Teledyne Oxygen sensor C06689-B1 for general purpose trace oxygen analysis

Intermittent or continuous monitoring of percent Oxygen (O2) in gas mixtures containing 0-100% Carbon Dioxide (CO2). 90% response time is 45 seconds
| A-1: Obsolete, contact factory | |||
| A-2C oxygen sensor | C6689-A2C | Used for trace O2 measurements in CO2 containing backgrounds (0.1-100% CO2). CO2 must be present. | Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. | 
| A-2CXL oxygen sensor | B74033-A2CXL | Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. | Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. | 
| A-2Cl: Obsolete, use A-2C | |||
| A-3: Obsolete, use A-5 | |||
| A-5 oxygen sensor | C6689-A5 | Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-100% CO2. 90% response is time is 45 seconds. | Has more tolerance to exposure to air than A-3. No restrictions on CO2 concentration. | 
| B-1 oxygen sensor | C6689-B1 | General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds). | Use B-3 or C-3 where longer life is required and response time is relatively unimportant. May be used to spot check flue gas. | 
| B-2C oxygen sensor | C6689-B2C | General purpose trace O2 analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm. | May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene. | 
| INSTA TRACE oxygen sensor | B71875 | Special patented construction provides rapid recovery, during initial cell installation, to low PPM levels by reducing the recovery period from several hours to just minutes. Low range limit is 0-10 ppm. | Used for trace O2 analysis in inert gas and hydrocarbon streams. | 
| B-2CXL oxygen sensor | C6689-B2CXL | Specially qualified B-2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm. | May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene. | 
| B-3 oxygen sensor | C6689-B3 | Percent O2 analysis, best compromise between long life and fast response. | May be used to spot check flue gas. | 
| B-4C oxygen sensor | C14613-B4C | Trace O2 cell specifically designed for the Model 317EXI. | Same performance as the B-2. | 
| B-5 oxygen sensor | C45091-B5 | Special application cell (non-standard) where long life and moderately fast response are required; B-5 has a factor of 3x the life of a B-3. | Requires 3x the amplifier gain of the B-3. Expected life is 36 months in air. | 
| B-5F oxygen sensor | C45091-B5F | Special application cell (non-standard) where long life and moderately fast response, in the presence of CO2, are required. | Uses Type F (acid electrolyte). Requires higher amplifier gain than normal. 90% response time is 13 seconds. Expected life in air is 6 months. | 
| B-7 oxygen sensor | C45091-B7 | Special application cell (non-standard) where fast response is required; the B-7 has a factor of 3x the life of a B-1 cell. | Requires 3x the amplifier gain of the B-1. Expected life in air is 24 months. | 
| B-7F oxygen sensor | C45091-B7F | Special application cell (non-standard) where moderate life and fast response, in the presence of CO2, are required. | Requires higher amplifier gain than normal. 90% response time is 7 seconds. Expected life in air is 3 months. | 
| C-1 oxygen sensor | C6689-C1 | Rarely used. Schematic for reference only. | |
| C-2 oxygen sensor | C6689-C2 | Rarely used. Schematic for reference only. | |
| C-3 oxygen sensor | C6689-C3 | Percent O2 measurements where maximum cell life is desired (high O2 applications). | 90% response time is 30 seconds. Expected life in air is 18 months. | 
| C-5 oxygen sensor | C45091-C5 | Special application cell (non-standard) where long life is required; the C-5 has a factor of 3x the life of a C-3 cell. | Requires 3x the amplifier gain of the C-3. Expected life in air is 54 months. | 
| C-5F oxygen sensor | C45091-C5F | Special application cell (non-standard) where long life, in the presence of CO2, is required. | Requires higher amplifier gain than normal. 90% response time is 30 seconds. Expected life in air is 9 months. | 
| C-6 oxygen sensor | C54090-C6 | Motion insensitive percent O2 measurements for use in hand held portable monitors. | Best cell for OEM safety applications. | 
| E-1 oxygen sensor | C14991-E1 | Special cell with performance characteristic of the C-3 with 5x the life. | Cell is 2 to 3 times the length of standard MFCs; requires special mounting. Designed for medical oxygen concentrators. | 
| E-2 oxygen sensor | C57283-E2 | Long life cell for use is the Model 3290 (for use in unattended air liquefaction nitrogen skids). | Has a 3 to 4 years expected life in air. Minimum range 0-1000 ppm. | 
| F-1R | C40371-F1R | 0-1000 ppm CO in Air | Used in Max 5 and 9950 Portable Combustion Analyzers | 
Common Models:
3000MA
  3010MA
  3110(311D)
  311TC
  3000TA
  311
  311XL
  311TCXL
  311PC
  3190
  320P
  3010PAC
  4020
  8800A
  INSTATRANS 3001
  INSTATRANS-XD
  3290
  A-2C
  L-2C
  B-2CXL
  A-5
  B-2C
  B-37937
  UFO-130-2
  C73870
  C65098A
  D67472REV8
  GB300
  INSTA TRACE (B71875)
  R-22A
Why choose GSI?
  1. 100% original product, 100% quality assurance.
  2. Varied payment methods.
  We adopt T/T, western union and paypal and Currency in EURO,USD,RMB
  3.SHIPPING:
  We can shipping all over the world.via DHL,UPS,Fedex,TNT and IPS,PDE,BRE,KARAPOST etc.


|   | 
| R17A Teledyne Analytical Instruments , Automotive Oxygen Sensors Images | 
 Fluke 700HTPK Hydraulic Test Pressure Kit
                                                                                    
                        
                        
                        
                                                            Fluke 700HTPK Hydraulic Test Pressure Kit
                                                    
                        
                     Fluke 2042 Cable Locator for Analytical Instruments Shipping Weight 3Kg Auto
                                                                                    
                        
                        
                        
                                                            Fluke 2042 Cable Locator for Analytical Instruments Shipping Weight 3Kg Auto
                                                    
                        
                     Fluke 710 mA Loop Valve Tester The Must-Have Analytical Instrument for Your
                                                                                    
                        
                        
                        
                                                            Fluke 710 mA Loop Valve Tester The Must-Have Analytical Instrument for Your
                                                    
                        
                     Fluke 700RG29 Pressure Gauge Calibrator -14 to 3000 psi Analytical Instruments
                                                                                    
                        
                        
                        
                                                            Fluke 700RG29 Pressure Gauge Calibrator -14 to 3000 psi Analytical Instruments
                                                    
                        
                     FLUKE 179 True RMS Digital Multimeter with Built-In Thermometer Cutting-Edge
                                                                                    
                        
                        
                        
                                                            FLUKE 179 True RMS Digital Multimeter with Built-In Thermometer Cutting-Edge
                                                    
                        
                     Fluke 707 Loop Calibrator with 0-28VDC Input Voltage and 0.015% Accuracy 3.5Kg
                                                                                    
                        
                        
                        
                                                            Fluke 707 Loop Calibrator with 0-28VDC Input Voltage and 0.015% Accuracy 3.5Kg
                                                    
                        
                     FLUKE 726 Precision Multifunction Process Calibrator 0-24V Input Voltage for
                                                                                    
                        
                        
                        
                                                            FLUKE 726 Precision Multifunction Process Calibrator 0-24V Input Voltage for
                                                    
                        
                     Fluke 116 HVAC/R Multimeter with Temperature and Microamps Input Voltage 0-20V
                                                                                    
                        
                        
                        
                                                            Fluke 116 HVAC/R Multimeter with Temperature and Microamps Input Voltage 0-20V
                                                    
                        
                     C06689-B2C Teledyne Analytical Instruments , Trace Teledyne O2 Analyzer
                                                                                    
                        
                        
                        
                                                            C06689-B2C Teledyne Analytical Instruments , Trace Teledyne O2 Analyzer
                                                    
                        
                     C06689-L2C Teledyne Analytical Instruments , Trace Teledyne O2 Analyzer
                                                                                    
                        
                        
                        
                                                            C06689-L2C Teledyne Analytical Instruments , Trace Teledyne O2 Analyzer